Negative Stain Electron Microscopy of Microtubules



Negative Stain Electron Microscopy of Microtubules (archive)

Protocol from Mitchison lab at Harvard medical school.

Negative staining is a rapid, qualitative method for analyzing microtubule structure at the EM level.